国国产日韩欧美一区二区久久精品_精品少妇人妻日韩欧美_中文字幕一区二区在线网站_惠民福利亚洲成人国产片女人爽到高潮网_高清欧美性暴力猛交_全免费A级毛片免费看69_久久香蕉综合色一综合色88个_日韩精品一区二在线91_1024免费无码视频_国产中文欧美国产私拍视频

+86-312-5907779
Products
Your location:home page > Products > Intelligent PDC series

GCS type low-voltage pull-out switch cabinet

Add time:2021-11-24 11:18:26   Number of views:813  

Product introduction

GCS type low-voltage pull-out switch cabinet is suitable for power plant, petroleum, chemical, metallurgy, textile, high-rise building and other industries of power distribution system. As a three-phase AC frequency of 50 (60) Hz, rated working voltage of 380V, 400V, 660V, Low-voltage complete set of distribution devices for power distribution, motor centralized control and reactive power compensation in generator and power supply systems with rated current of 4000A and below.

GCS type low-voltage withdrawl switchgear is designed and developed by two joint design groups according to the requirements of the competent departments of the industry, the majority of electric power users and design units. It conforms to the national conditions, has higher technical performance indicators, can adapt to the development of the electric power market and can compete with the existing introduced products.

Using the environment

● Ambient air temperature is not higher than +40℃, not lower than -5℃. The average temperature within 24 hours shall not be higher than +35℃.

● For indoor use, the altitude of the site shall not exceed 2000m.

● The relative humidity of the surrounding air is not more than 50% at the highest temperature of +40℃. The relative humidity is allowed to be larger at the lower temperature, such as 90% at +20%. It should be taken into account that the influence of condensation may occur occasionally due to the change of temperature.

● When installing the device, the inclination of the vertical plane is not more than 5°, and the whole cabinet column is relatively smooth (in line with GBJ232-82 standard).

● The device should be installed in no violent vibration and impact and not enough to make the electrical components should not be corroded.

● Users have special requirements, can negotiate with the manufacturer to solve.

Ordering instructions

The order contract contains the following contents:

● List of cabinet components;

● The full model of the product includes the main circuit scheme number and auxiliary circuit scheme number;

● Main circuit system combination sequence diagram;

● Auxiliary circuit electrical schematic diagram;

● Circuit voltage, current, time and other setting parameters;

● Other special requirements inconsistent with normal use of the product.

Structural characteristics of

The main frame adopts 8MF type open steel, the two sides of the steel respectively have module 20mm and 100mm φ9.2mm mounting holes, internal installation is flexible and convenient.

The main frame assembly is designed in two ways, full assembly structure and part (side frame and beam) welding structure, for users to choose.

Each functional room of the core device is isolated from each other, and the compartment is divided into functional unit room, bus and cable room. The function of each chamber is relatively independent.

The horizontal main bus is arranged in a horizontal position after the cabinet to enhance the anti-electric bus; It is the basic measure to make the main circuit of the device have high short-circuit strength ability. The design of cable compartment makes the cable up and down are very convenient.

The module of the drawer height is 160mm. It is divided into five size series of 1/2 unit, 1 unit, 1.5 unit, 2 unit and 3 unit. Unit loop rated current 400A and below <> drawer changes only in the height size change, its width, depth size unchanged. The drawers of the same functional unit have a maximum of 11 single drawers or 22 1/2 unit drawers per MCC cabinet.

The drawer panel has the obvious signs of the position such as dividing, closing, testing and pulling out. Drawer units have mechanical interlocking devices.

Main circuit fixed voltage(V)

AC380(400)、(660)

Auxiliary circuit rated voltage(V)

AC220、380(400)     DC110、220

Rated frequency(HZ)

50(60)

Rated insulation voltage(V)

660(1000)

Rated current(A)

The level of bus

≤4000

Vertical busbar(MCC)

1000

Bus-rated peak tolerance current(kA/1s)

50、80

Rated peak withstand current of bus(kA/0.1s)

105、176

Power frequency test voltage(V/1min)

 Main circuit

2500

Service circuit

1760

 Generatrix

Three phase four wire system

A、B、C、PEN

Three phase five wire system

A、B、C、PE、N

 Protection grade

IP3L0、IP4L0

Copyright ? Hebei Bowei Electric Co., LTD. http://newlogic.cn All Rights Reserved    
HomeTelProduct